Valco Instruments Co. Inc.
8/13
Dynacalibrator
Model 235
Instruction Manual
Valco Instruments Co. Inc.
800 · 367· 8424 sales
713
· 688· 9345 tech
713
· 688· 8106 fax
VICI AG International
Schenkon, Switzerland
Int + 41
· 41 · 925· 6200 phone
Int + 41
· 41 · 925· 6201 fax
North America, South America, and Australia/Oceania contact: Europe, Asia, and Africa contact::
Manufactured by:
Valco Instruments Co. Inc.
8300 Waterbury
Houston, TX 77055
Vue de la page 0
1 2 3 4 5 6 ... 30 31

Résumé du contenu

Page 1 - Instruction Manual

Valco Instruments Co. Inc. 8/13 Dynacalibrator Model 235 Instruction ManualValco Instruments Co. Inc.800 · 367· 8424 sales 713 · 688· 9345 tech 713

Page 2 - Symbols used in this document

6Unit LocationIn general, the Dynacalibrator should be as close as possible to the analyzer to be calibrated, as long as:• theambienttemperatureis

Page 3 - Table of Contents

7Rear Panel ConnectionsRemove all shipping caps and shipping plugs from the rear panel bulkhead fittings. All these hardware items should be saved fo

Page 4

8Span OutletThe primary outlet on the Model 235 is labeled SPAN OUT. The SPAN OUT port may be either permanently plumbed to the calibrate input port

Page 5 - Introduction

9OVEN TEMPERATURE UPPER LIMIT A power-limiting thermostat provides a safety shutoff at this user-defined setpoint, usually 5-10 degrees above the norma

Page 6

10Initial Set-UpConnections1. Plug the supplied power cord into the rear mounted power supply. Ensure that the power supply output cable is plugged

Page 7 - Specifications

11NOTE: The Ready status light will be red while the oven is changing temperature. Once the oven temperature is within the control limits, the statu

Page 8 - Getting Started

125. Turn off the power switch and wait 15-20 minutes for the chamber to cool.6. Turn on the heater power switch and set the chamber operating tempe

Page 9 - Concealed Damage

13ConfigurationThe Model 235 has been designed to provide high accuracy dilution of permeated gases in both automatic and manual operation modes with m

Page 10 - Unit Location

14Tubes Screen Select the Tubes screen by touching the “Tubes” tab on the left hand side of the display. On this screen, the following parameters ar

Page 11 - Rear Panel Connections

15Basic OperationImportant Permeation Device Considerations• Ifmorethanonetubeistobeusedintheovenatthesametime,orderallthetubes wi

Page 12 - Front Panel Features

AttentionRadiant heat warningEntanglement warningElectrical warningSymbols used in this document

Page 13

16Once the correct values are input in the correct fields, select the "Enable” button on the lower right hand portion of the Manual screen. If th

Page 14 - Initial Set-Up

17Basic Operation4. Select the particular tube to be used as the basis for calculations by touching on the tube name. The pull down will roll up and

Page 15 - READY STATUS LIGHT

18Status indicator A red indicator means Not Ready, which can reflect one or more of the following: •Flowoutsideoftolerances •Temperatureoutsid

Page 16

19 Basic Operationselect from the installed devices, and the graph will update with the histori-cal data of the selected device. Use your finger to sc

Page 17 - Configuration

20Analyzer CalibrationWhen the power-up procedure is completed and the chamber temperature, flow, and permeation device have reached equilibrium, the s

Page 18 - Tubes Screen

21Shutdown ProcedureDynacalibrators are designed to operate continuously; however, if it is necessary to turn the unit off, use the following procedur

Page 19 - Basic Operation

22Advanced Theory of OperationDynacalibrator operation is based on the principle of mixing a known mass flow of gas permeation device with a metered st

Page 20 - Auto Mode

23Electrical DescriptionDynacalibrators are powered from a benchtop style transformer on the rear panel. This is a switcher-style supply that allows

Page 21 - Quick Glance Status Bar

24MaintenanceSince Dynacalibrators are designed for and generally used in applications that require continuous service, a planned routine maintenance

Page 22 - Historical Display Graph

259. Rinse the fan screen and fan filter in clean water and blow dry with low- velocity air. 10. Reinstall the fan, fan filter, fan screen brackets

Page 23

Table of ContentsIntroduction General Description...

Page 24 - Analyzer Calibration

26

Page 25 - Shutdown Procedure

27WarrantyThis Limited Warranty gives the Buyer specific legal rights, and a Buyer may also have other rights that vary from state to state. For a per

Page 26 - Advanced Theory of Operation

If this equipment is used outside manufacturers’ specification the protection provided by the equipment may be impaired.

Page 27 - Electrical Description

1IntroductionGeneral DescriptionVICI Metronics Dynacalibrators® use Dynacal® permeation devices to generate the precise gas concentrations necessary f

Page 28 - Maintenance

2IntroductionFigure 1: Model 235 plumbing schematic

Page 29

3SpecificationsIntroduction  

Page 30 - Model Number Breakdown

4Getting StartedEvery Dynacalibrator is completely calibrated, thoroughly tested and inspected, and carefully packed prior to shipment. The carrier h

Page 31 - Warranty

5Concealed DamageConcealed damage is damage which is not apparent until after the equipment has been unpacked and examined or tested. In the event tha